There are two components to the Naviclient install. Hi, We have EMC Clariion CX4-120 intergrated to Windows 2008 64 bit server as a host with multipathing configured with Power path 5.5, off late we are getting error. Installing PowerPath in a cluster requires downtime (to install or upgrade). The recommended way is to install PowerPath one node at a time. You can have MPxIO and. DB:4.05:Powerpath Problems With Windows 2003 Enterprise 64 Bit Edition 8z. Hi Guys,I would like to clarify a few things about Powerpath here if possible.a). Official Intel Drivers download center, download and install Intel PowerPath* for Windows* 2003 64 bit PowerPath* Windows* 2003 64 bit for the Intel® Storage System SSR212PP based on EMC AX150* Technology. For anyone who has the misfortune of having to install a multi-node RAC cluster of Oracle 11g R2 on Solaris 10 (in my case, SPARC 64-bit) with an EMC PowerPath. W2k. 12 R2 native MPIO vs. EMC Power. Path. Hi everyone,We're in the process of creating the unattende installation of W2k. R2 for our company and making all. MPIO with MS i. SCSI Initiator and Power. Path. Multipath Connection to CX3- 2. SCSI LUN Using MS MPIO and EMC Power. Path. The following set of screen shots document creating multipath connections to i. SCSI LUNs on a Dell. The server connecting to the CX3- 2. SCSI LUN was server r. Emc Powerpath Commands For AixWindows Server 2. R2. As shown in the following network diagram and Navisphere screen shot, each CX3- 2. SP) had four i. SCSI front end ports of which two were used in this demo, with one each in the 1. The r. 3win. 29. 50a was connected to both network subnets. The EMC Navisphere Server Utility was used to register the r. SCSI initiator’s i. SCSI Qualified Name (IQN) with the a. CX3- 2. 0c array. Then LUNs were created and placed in the same storage group as the r. LUNs owned by SP A and two owned by SP B): On the r. Microsoft i. SCSI Initiator 2. Initiator- 2. 0. 4- build. EMC’s Power. Path 4. EMCPP. W2. 00. 3. Note the port address (a. IQN): Using the Log On function a connection was made to port a. Connections were then made to ports a. With the first target selected, the Details screen was brought up: All four LUNs appeared on the Devices tab: The Advanced features of the four devices were selected in turn. On the MPIO tab for each LUN “Vendor Specific” was showing, which indicates that Power. Path will be used for failover/load balancing: The Power. Path Monitor showed four paths to each LUN, one for each port. Although all four paths were shown as “Active”, only the two connecting to ports on the storage processor to which the LUN is currently assigned will be in use at any given time. If the paths to both ports of that storage processor are disabled, the CX3- 2. LUN to the other storage processor. The LUNs were now present in Disk Management where they were initialized, assigned a disk letter and had partitions created on them: Note that connections must be made to four ports on the CX3 array for complete multipathing. This leaves four additional i. SCSI front end ports that may also be connected and assigned to a separate server for load balancing.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
August 2017
Categories |